GTe/GTe-F Self-limiting heating cable for downpipe protection

GTe is installed for ice protection of roof gutters and downpipes and frost protection of drain systems. GTe-F is installed in chemically hazardous zones, such as gutters and downpipes of bitumen roofs, car parking areas and sewerage systems.

GTe2 is a self-limiting heating cable of 18/36 W/m output for ice protection of roof gutters and downpipes, and frost protection of drain systems. It automatically adjusts its output in response to ambient temperature. The cable is UV resistant. The cable is produced with nanotechnologies, ensuring for long-lasting properties benefits of roof systems.

GTe2-F self-limiting heating cable with fluorpolymer overjacket can be installed in chemically hazardous zones, such as gutters and downpipes of bitumen roofs, car parking areas and sewerage systems. The cable is available in 200-300 m reel.

 

Output  18 W/m (at 0 °C)
36 W/m (in ice at 0 °C)
Voltage 220/240 V AC
Dimensions  10,5×5,9 mm
Overjacket
• GTe 

• GTe-F 
UV resistant
Thermoplastic
Fluoropolymer (F)
Min. bending radius  35 mm
Max temperature +65 °C ON or OFF
Min. instal. temperature  –30 °C
gte lentele_EN

A – In snow and ice water the heating cable will operate at full power.
B – As the snow begins to melt and the water drains away, the heating cable self-regulates to half power.
C– As it gets warmer, the heating cable will reduce its power output.

Maximum length of the cable (m) in one electrical circuit depending upon the temperature

Ambient temperature 230 V
6 A  10 A  16 A 20 A   32 A
+10 °C 26 42 68 84 90
0 °C 24 38 62 78 86
–20 °C 20 34 54 68 80

 

Type  Order No. 
GTe2  30116020
GTe2-F 30116021